Sign In | Join Free | My wneducation.com
China Zhangjiagang HuaDong Boiler Co., Ltd. logo
Zhangjiagang HuaDong Boiler Co., Ltd.
Zhangjiagang HuaDong Boiler Co., Ltd.
Verified Supplier

9 Years

Home > Superheater Coil >

Heat Resistant Firm Structure ASME Standard Superheater Coil

Zhangjiagang HuaDong Boiler Co., Ltd.
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

Heat Resistant Firm Structure ASME Standard Superheater Coil

  • 1
  • 2
  • 3

Brand Name : HD BOILER

Model Number : Rear Wall Evaporator

Certification : ISO9001 , SGS , TUV , ASME , EN

Place of Origin : Zhangjiagang,China

MOQ : 5 tons

Price : Negotiable

Payment Terms : L/C, T/T, Western Union

Supply Ability : 800 Tons / Month

Delivery Time : 60 Days

Packaging Details : Steel Frame

Material of Tube : SA106 Gr. B and SA192M

Product Name : Rear Wall & Evaporator

Standard : ASME

Application : Sugar Mill and Power Plant Boilers

Keyword : Evaporator Coils and Serpentine Coils

Material of Fin : Q235B

Contact Now

High Temperature Evaporator Serpentine Coils Assembly ASME Standard


Introduction

For over 30 years, Hua Dong Boiler has been consistently innovating and improving our boiler spare parts. The improvements in bending, welding and design ensure our products meet both European and American standards, ensuring a reliable performance.

Serpentine tube is a tube that twists and turns several times in a plane.The convection heating surface of the boiler, such as economizer, superheater and reheater, adopts the structure of serpentine tube through the belt, with horizontal and vertical layout.

Evaporative tube bundle is an evaporative tube bundle mainly absorbing convection heat transfer in small and medium capacity boiler. It is generally a bundle of dense staggered tube system composed of ascending and descending tubes connected with upper and lower drum.Evaporation tube bundle pipe heat load is high, this part of the pipe by hot water into steam, from the bottom up;Its main function is to absorb heat to the water and steam and to serve as the rising part of the boiler water cycle.

1. Material composition: It is made up of snake-like tubes (carbon steel, alloy steel or heat-resistant steel, etc.) and collection boxes and other supporting material. Tubes generally have 32, 38, 42 or other types of specifications, according to user's needs separately.
2. Arrangement: vertical or horizontal layout.
3. Features: beautiful appearance, size, accuracy, first-class bending and welding technology, first-class detection equipment.

Superheater
Fossil fuel power plants often have a superheater section in the steam generating furnace.The steam passes through drying equipment inside the steam drum on to the superheater, a set of tubes in the furnace. Here the steam picks up more energy from hot flue gases outside the tubing, and its temperature is now superheated above the saturation temperature.

Reheater
Power plant furnaces may have a reheater section containing tubes heated by hot flue gases outside the tubes. Exhaust steam from the high-pressure turbine is passed through these heated tubes to collect more energy before driving the intermediate and then low-pressure turbines.

Type
Advantages
Disadvantages
Supporting method
Pendant-type
1.Firm structural support
1. Flow blockage by condensed steam 2. Needs slow restart to purge the water that accumulates in the bottom.
supported from above
Inverted-type
1.Proper drainage of the condensed steam
1. Lack the structural rigidity, especially in high speed gas flow
Supported from below
Horizontal -type
1. Proper drainage
2. Good structural rigidity
1. They do not view the flam directly so they are mainly from the convective type
Usually supported in the vertical gas ducts parallel to the main furnace.

Heat Resistant Firm Structure ASME Standard Superheater Coil

The drawing here is the evaporator assembly with membrane wall and evaporator coils for your reference.

This project also include steam drum+header+economizer.

Heat Resistant Firm Structure ASME Standard Superheater Coil

DESIGN AND FABRICATION CODE ASME SECTION I, 2019 EDITION
DESIGN PRESSURE 8.1 MPa
MAX. ALLOWABLE WORKING PRESSURE 8.1 MPa
DESIGN TEMPERATURE 320℃
HYDROSTATIC TEST PRESSURE 12.2 MPa
CORROSION ALLOWANCE 0.5mm


Product Tags:

heat resistant Superheater Coil

      

firm structure Superheater Coil

      

heat resistant boiler superheater

      
Buy cheap Heat Resistant Firm Structure ASME Standard Superheater Coil product

Heat Resistant Firm Structure ASME Standard Superheater Coil Images

Inquiry Cart 0
Send your message to this supplier
 
*From:
*To: Zhangjiagang HuaDong Boiler Co., Ltd.
*Subject:
*Message:
Characters Remaining: (0/3000)